Optex Incorporated

 

1845  W.  205th St. Torrance, CA 90501-1510 USA

TEL (310) 533-1500 and (800) 966-7839

FAX (310) 533-5910

 

Description

 

Doc:       Architect/ Engineer Specifications

Model:    AX-100 PLUS/ AX-200 PLUS

AX-100 ALPHA/ AX-200 ALPHA Desc:     Outdoor Short-Range Photoelectric

Intrusion Detector

 

 

NOTE:  Words/statements within square brackets [ ] may be included when appropriate, or when selection is required.

 

 

The Intrusion Detector[s] shall operate on  the   Verified  Intrusion  principle  using Infrared Photoelectric, and shall be Listed by Underwriter's Laboratories, Inc..

 

 

OUTPUT AND ENCLOSURE

 

[Each] [The] detector shall provide  the detection,  signal  processing,  alarm  relay, and operating power  circuitry in the same enclosure; and shall provide an alarm relay actuation upon the  detection  of  an intruder moving into or through its protection pattern. The  housing  cover  and  chassis  shall  be highly durable and heat resistant, and shall be capable of  mounting to a Wall or Pole without modification.

 

The total weight (both Transmitter and Receiver) shall be 36.7 oz. (1040g).

 

[Each]   [The]  detector  shall  feature  a single  piece  electronic  logic  board  whose circuitry  is   specifically  designed  for  this detector alone, and which has sustained  a substantial “Burn-in” test for several days.

 

[Each]  [The]  detector shall also feature rain,  dust,  and  Insect  Protection. The Rubber O-Ring and Rubber Grommets used in [each] [the] model shall prevent rain, dust, and  tiny  insects  from  adversely  affecting performance (IP55).

 

 

LED OPERATION

 

The   detector[s]   shall    incorporate    a single,  Red LED to indicate the operating conditions.      Red   LED   illuminated   shall indicate  an  alarm condition.  Red LED not illuminated   shall   indicate   a   non-alarm condition.

 

The LED indicator shall feature a 3 Step Process  for  fast  and  accurate  fine  beam adjustment.  On [each] [the] ALPHA version detector,  the  alignment  condition  shall  be visually  displayed  on  the  front  and  in  the viewfinder of the receiver.  By simply aiming both units and watching the LED indicators, accurate   and  reliable  alignment  shall  be achieved.    The  alignment  status  at  the receiver shall be optically transferred to the transmitter  and  shall  be  indicated  by  the LEDs. 

 

To align the transmitter,  one  shall simply monitor the LED level while adjusting. The LED shall be “ON”  before  alignment, “Flickering”  when  Beam  energy  from  the transmitter   is  reaching  the  receiver,  and “OFF”  when  the  beam  is  ready  for  fine tuning.  Fine tune  adjustment  shall  always be done with a Volt Meter.

 

POWER REQUIREMENT

 

The  detector[s]  shall   be   capable   of operating  from  a  DC  power  source  rated within the range of 10.5 to 25 volts DC.  The current   draw   (transmitter  +  receiver)  for models  AX-100  PLUS  and  AX-200  PLUS shall be a maximum of 46 mA during normal operation.  The current draw  (transmitter  + receiver)  for  models  AX-100  ALPHA  and AX-200  ALPHA  shall  be   40   mA   during normal  operation,  and  46mA  (maximum) during optical alignment.

 

Doc #:  3440-0322

 

ALARM OPERATION

 

A condition of alarm shall occur  when the  alarm  conditions  are  met.  The  Beam Interruption Period shall be adjustable within the range of 50 ~ 500 msec. to increase stability while maintaining reliability at every installation  site.     A  selectable  4  channel beam        frequency  with        automatic synchronization    shall    be    available    for models AX-100 ALPHA and AX-200 ALPHA. The  beam  characteristics  shall  be  pulsed infrared.   The Alarm Period shall be 2.0 ± 1 seconds  nominal.  

 

The Alarm Output shall be  capable  of handling 28VDC, 0.2A max., Form C Relay.  [Each]  [The]  detector  shall signal the condition of alarm using a Form C Relay with terminal strip  connections.   The detector[s]   shall   also   contain   a   tamper switch on the receiver only  that  shall  open when the cover is removed.

 

 

SENSOR STABILITY

 

[Each]   [The]   detector   shall    feature protection  against  Lighting  and  High  EMI Disturbances.    An  improved  EMI   Surge Absorber  and  High  Surge  Resistiveness Relay shall maintain stable  operation  even in the most lightning prone areas, and shall remain stable against over 14kV of lightning surge.

 

[Each]  [The]  ALPHA  version  detector shall also utilize  selectable beam frequencies to eliminate cross talk of Beams and to provide accurate beam discrimination. The  selectable  4  channel beam frequency with automatic synchronization shall be used to avoid cross talk  problems  that  occur   when   using   2 photobeams  for  long  distance  or   beam stacking applications.

 

[Each] [The] detector shall remain stable even in high temperature conditions.  [Each] [The] detector  shall  be   rated   to   operate within  a  temperature range  of  [minus  13° Fahrenheit to Plus 131° Fahrenheit]  [minus 25°  Celsius  to  Plus  55°  Celsius].   

[Each] [The] detector shall also tolerate a humidity rate of 95% max.  No false

alarm shall occur within these operating conditions.

 

[Each]  [The]  detector  shall  contain  an A.G.C.  (Automatic Gain Control) Circuit to continually monitor for gradual  changes  in the  signal’s  strength 

caused  by  changing weather  conditions.    It  shall  adjust  the sensitivity accordingly to maintain the proper signal  level  for  the  current  environmental conditions.

 

[Each]   [The]   detector   shall    provide protection against rain, dust, and insects by means of a sealed enclosure housing.  The Rubber   O-Ring   and   Rubber   Grommets (IP55)  used in the detector[s] shall prevent rain,  dust, and tiny insects from adversely affecting performance.

 

[Each] [The] detector shall feature  frost and  dew  protection.  An  anti-frost   and convex visor design shall be incorporated to protect the detector[s] from the effect of frost or snow.

 

[Each] [The] detector shall utilize  Twin Synchronized    Pulsed   Beams   with   size analysis technology to eliminate false alarms due  to  birds  or  flying  objects.  The  “And Gate” dual beams shall  require simultaneous interruption of both beams  to trigger an activation.

 

No activation shall be generated  when  a  bird  or  falling   leaves break just one beam.

 

LENS AND DETECTION PATTERN

 

[Each]  [The]  detector  shall  contain  a durable and high grade Aspherical lens that shall focus received infrared energy onto the sensor. 

 

The sensor and module combined shall   create   more   sharply   defined   and precise infrared beams compared to  those created by ordinary lenses.

 

The  precise  area of the detection field shall be specific to each model.  Model AX- 100  PLUS shall feature a detection field of 100ft   (30m)   Outdoor,   and   200ft   (60m) Indoor, with a Maximum  Arrival Distance of 1000ft (300m).  Model AX-200 PLUS shall feature  a  detection  field  of  200ft  (60m) Outdoor,  and  400ft  (120m)  Indoor,  with  a Maximum Arrival Distance of 2000ft (600m). Model   AX-100   ALPHA   shall   feature   a detection  field  of 100ft (30m) Outdoor, and 200ft (60m) Indoor, with a Maximum Arrival Distance of 1000ft (300m).    Model AX-200 ALPHA  shall  feature  a  detection  field  of

 

Doc #:  3440-0322

 

 

200ft   (60m)   Outdoor,  and  400ft  (120m) Indoor, with a Maximum Arrival Distance of 2000ft (600m).

 

The mounting height of the  detector[s] shall be within the range of 0.8 ~ 1.2m (2.7 ~ 4ft).

 

Fine optical beam alignment shall  also be  incorporated  into  the  detector[s].    The rotating dial shall allow the installer to finely adjust  the  beam  easily  either  horizontally (180°/ ± 90°) or vertically (10°/ ± 5°), with or without the use of a screw (finger adjustable).

 

MODEL

 

The Intrusion Detector shall be  model AX-100 PLUS (Outdoor Short-Range Photoelectric Intrusion Detector) [or] [model AX-200 PLUS] [or] [model AX-100  ALPHA][or] [model AX-200 ALPHA], [with] [optional Back Cover BC-2] [or] [optional Heating Unit HU-2].

 

 

Doc #:  3440-0322